Recovery Mode - IBM pSeries 670 Service Manual

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Recovery Mode

If the service processor detects that its programming has been damaged when it is powering on to
standby mode, it will enter recovery mode. In recovery mode, it will ask for the firmware update diskettes
by putting eight-digit codes on the operator panel.
The eight-digit codes are as follows:
Code
A1FD 0000
A1FD 0001
A1FD 0002
A1FD 0003
A1FD 000n
Notes:
1. If the wrong diskette is inserted at any time, or if the diskette is left in the drive after it has been read,
B1FD 001F is displayed, indicating that the wrong diskette is in the drive.
2. If B1FD 001A is displayed at any time during the process, the service processor must be reset by
activating the pinhole reset switch on the operator panel.
After the update process is complete, the service processor resets itself and goes through a complete
reboot.
Action
System firmware has been damaged and must be reflashed.
Insert update diskette 1.
Insert update diskette 2.
Insert update diskette 3.
Insert update diskette n.
Chapter 7. Using the Service Processor