Error Code Description
406F 0007 Error code generation/logging detected fault in
L3 VPD card
406F 000A Error code generation/logging detected fault in
I/O book 1 (slot 0)
406F 000B Error code generation/logging detected fault in
primary I/O book (slot 1)
406F 000C Error code generation/logging detected fault in
I/O book 3 (slot 2)
406F 000D Error code generation/logging detected fault in
I/O book 4 (slot 3)
406F 000E CUoD capacity card
406F 0010 Error code generation/logging detected fault in
Memory book (slot 0)
406F 0011 Error code generation/logging detected fault in
Memory book (slot 1)
406F 0012 Error code generation/logging detected fault in
Memory book (slot 2)
406F 0013 Error code generation/logging detected fault in
Memory book (slot 3)
406F 0014 Error code generation/logging detected fault in
Memory book (slot 4)
406F 0015 Error code generation/logging detected fault in
Memory book (slot 5)
406F 0016 Error code generation/logging detected fault in
Memory book (slot 6)
406F 0017 Error code generation/logging detected fault in
Memory book (slot 7)
406F 00B0 Error code generation/logging detected possible
problem with bus controller or CSP code
406F 00B1 Error code generation/logging detected possible
problem with bus controller
Action/
Possible Failing FRU
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Memory book (slot 2)
Location: U1.18-P1-M7
Memory book (slot 3)
Location: U1.18-P1-M6
Memory book (slot 4)
Location: U1.18-P1-M4
Memory book (slot 5)
Location: U1.18-P1-M8
Memory book (slot 6)
Location: U1.18-P1-M5
Memory book (slot 7)
Location: U1.18-P1-M1
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index