Error Code Description
406E 0C12 Scan control routines detected mismatch
between MCM 1 and VPD card
406E 0C13 Scan control routines detected mismatch
between MCM 3 and VPD card
406E 0CA5 Scan control routines detected invalid processor
subsystem configuration
406E 0CA6 Scan control routines detected no usable main
storage
406E 0CA9 Scan control routines detected configuration
error with processor memory
406E 0D00 Scan control routines detected fault in L3 cache
module 0
406E 0D01 Scan control routines detected fault in L3 cache
module 1
406E 0D02 Scan control routines detected fault in L3 cache
module 2
406E 0D03 Scan control routines detected fault in L3 cache
module 3
406E 0D04 Scan control routines detected fault in L3 cache
module 4
406E 0D05 Scan control routines detected fault in L3 cache
module 5
406E 0D06 Scan control routines detected fault in L3 cache
module 6
406E 0D07 Scan control routines detected fault in L3 cache
module 7
406E 0D08 Scan control routines detected fault in L3 cache
module 8
406E 0D09 Scan control routines detected fault in L3 cache
module 9
406E 0D0A Scan control routines detected fault in L3 cache
module 10
406E 0D0B Scan control routines detected fault in L3 cache
module 11
406E 0D0C Scan control routines detected fault in L3 cache
module 12
406E 0D0D Scan control routines detected fault in L3 cache
module 13
406E 0D0E Scan control routines detected fault in L3 cache
module 14
406E 0D0F Scan control routines detected fault in L3 cache
module 15
592
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1