IBM pSeries 670 Service Manual page 509

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Error Code Description
4067 0B15 Bus tests detected fault in I/O book
4067 0B16 Bus tests detected fault in I/O book
4067 0B17 Bus tests detected fault in I/O book
4067 0B20 Bus tests detected fault in I/O book
4067 0B21 Bus tests detected fault in I/O book
4067 0B22 Bus tests detected fault in I/O book
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H3
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H3
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H3
4. Call service support.
Chapter 5. Error Code to FRU Index
489