Error Code Description
4508 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
4508 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
4508 305C Memory subsystem and other bus tests
detected fault in 4 GB inner memory book
4508 305D Memory subsystem and other bus tests
detected fault in 4 GB outer memory book
4508 305E Memory subsystem and other bus tests
detected fault in 16 GB inner memory book
4508 305F Memory subsystem and other bus tests
detected fault in 16 GB outer memory book
4508 307A Memory subsystem and processor subsystem
tests detected fault in 4 GB inner memory book
4508 307B Memory subsystem and processor subsystem
tests detected fault in 8 GB inner memory book
4508 307C Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
4508 307D Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
45084 307E Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
4508 308A Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4508 308B Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4508 308C Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4508 308D Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4508 308E Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4508 30BD Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
inner memory book
4508 30C3 Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
inner memory book
4508 30C6 Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
outer memory book
4508 30CC Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
outer memory book
Action/
Possible Failing FRU
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Chapter 5. Error Code to FRU Index