Thermo Scientific APEX 100 User Manual page 421

Apex series
Table of Contents

Advertisement

4
D
C
50
1.97
155
6.09
A (APERTURE WIDTH)
A + 230[9.06]
4X
32
1.26
4X M10X1.5
B
CABLE
PORT
A + 100[3.94]
A
SEE SHEET 1 FOR REVISION INFORMATION
REV
ECO
4
3
75
2.95
100 [3.94] FOR B=50 ONLY
EPOXY LINED
B
APERTURE
(APERTURE HEIGHT)
75
2.95
50 1.97
75
2.95
12[.47]
(E)
(HEAD WIDTH)
2X D
2X E
2X 25 .98
DESCRIPTION
3
B (APERTURE
HEIGHT, mm)
100
150
200
50
145
145
145
75
145
145
145
100
145
145
125
145
145
150
145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250
175
145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250
200
225
250
4X
12
.47
75[2.95]
C
145[5.71]
OR
250[9.84]
TOLERANCE UNLESS SPECIFIED:
ALL DIMENSIONS ARE IN MILLIMETERS AND [INCHES]
X
X.X
75[2.95]
X.XX
ANGLES
REMOVE ALL BURRS & UNNECESSARY
SHARP EDGES
This document is confidential and is the property of Thermo Fisher
Scientific ("Thermo"). It may not be copied or reproduced in any
manner without the expressed written consent of Thermo. This
document also is an unpublished work of Thermo. Thermo intends to
and is maintaining the work as confidential information. Thermo also
may seek to protect this work as an unpublished copyright. In the
event of either inadvertent or deliberate publication, Thermo
intends to enforce it's rights to this work under the copyright laws as
a published work. Those having access to this work may not copy,
use or disclose the information in this work unless expressly
authorized by Thermo.
BY
APP
DATE
2
RECTANGULAR APERTURE HEADS: C (HEAD WIDTH, mm)
A (APERTURE WIDTH, mm)
250
300
350
400
145
145
145
145
145
145
145
145
145
145
145
145
145
145
145
145
145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250
145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250
145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250 145 OR 250
mm[INCH]
145[5.71]
250[9.84]
AUDIT CHECK
(OPTIONAL)
HORIZONTAL APERTURE
HORIZONTAL PRODUCT FLOW
ENGINEER:
DATE:
DMG
5/31/07
DATE:
DRAWN BY:
5/31/07
DMG
DATE:
CHECKED BY:
5/31/07
DMG
APEX 300 OUTLINE AND MOUNTING
PART NUMBER:
810108
DRAWING NUMBER
SCALE
SIZE
1:3
B
PROJECTION
Derived From:
2
1
450
500
550
145
145
145
D
145
145
145
145
145
145
145
145
145
SQUARE APERTURE HEADS
A & B (mm)
C (mm)
75
145 OR 250
100
145 OR 250
125
145 OR 250
150
145 OR 250
175
145 OR 250
C
200
145 OR 250
225
145 OR 250
250
145 OR 250
275
250
300
250
325
250
350
250
FOOT DIMENSION TABLE
C
D
E
mm[INCH]
mm[INCH]
100[3.94]
22.5[.89]
200[7.87]
25[.98]
B
A
REV
SHEET
07387M-B300
B
2 of 5
© 2007, by Thermo Fisher Scientific
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apex 300Apex 500

Table of Contents