Assigning The Input For The Reject-Confirm-1 Photo Eye (Reject 1); Assigning The Input For The Bin-Full Photo Eye (Reject 1) - Thermo Scientific APEX 100 User Manual

Apex series
Table of Contents

Advertisement

Assigning the Input for the Reject-Confirm-1 Photo Eye
(Reject 1)
This function assigns the input for the reject-confirm-1 photo eye. In a conveyor
application, for example, the reject-confirm-1 photo eye monitors reject-bin number 1,
and verifies that the reject has actually occurred.
Reject Confirm 1 Input
1) Press the Go button and an input screen appears.
2) Make the appropriate assignments for input (Input 1–6) and polarity (+ or –).
3) Press the Go button to save your settings.
4) Press the Back button to exit the menu.

Assigning the Input for the Bin-Full Photo Eye (Reject 1)

This function is used only in conveyor applications and assigns the input for the bin-full
photo eye. This photo eye can be installed half-way up or three-quarters of the way up
the bin, giving you some warning before the bin is completely full. (In our example, both
the reject-confirm and bin-full photo eyes are assigned to Output 3, which is a common
set-up in conveyor applications.)
Bin Full Input
1) Press the Go button and an input screen appears.
2) Make the appropriate assignments for input (Input 1–6) and polarity (+ or –).
3) Press the Go button to save your settings.
4) Press the Back button to exit the menu.