Setting the Latching-Reject Function (Reject 1)

This function can only be used to latch your reject-1 device. The default setting for the
latching-reject function is "off," as shown by the X next to the padlock icon in the screen
below.
Latching Reject
Example of Using the Latching-Reject Function
The latching-reject function is normally used only in conveyor applications, where shop-
floor personnel are responsible for manually removing contaminated product from the
conveyor. When contaminants are detected, the detector sends a signal, which remains
on ("latched") until manually reset. The output signal to the conveyor or buzzer remains
latched on, until manually reset by the operator.
Enabling the Latching-Reject Function
To enable the latching-reject function, do the following.
1) Make sure the latching-reject function is highlighted, as shown above.
2) Press the Go button and a check mark appears. The latching-reject function is now
active.
Latching Reject
3) Press the Back button to exit the function.
Page 122