Setting Amplitude Suppression (Reject 1)

This function is normally used only in gravity-feed and pipeline applications, and is used
in conjunction with the suppression-time function described above. The amplitude-
suppression function is used to tell the detector how much amplitude suppression to
apply to the vibration signal affecting the search head. This is important because
vibrations generate a vibration signal in the search head, and these may have the same
characteristics as a contaminated product signal. As a result, the detector may interpret
vibration as contamination.
Suppression Amplitude
Keying In a Value for Amplitude Suppression
To key in a value for amplitude suppression, do the following.
1) Follow steps 1–3 in the section above to get to page 3 of the rejects menu.
Reject Suppression
2) Navigate to the amplitude-suppression function and make sure it is highlighted.
Suppression Amplitude
(continued...)
Page 134
Thermo Scientific APEX User's Guide