System and Tools—Page 2
1) From the Main Menu navigate to the system and tools menu.

System and Tools

2) Press the Go button and page 1 of the system and tools menu appears. Navigate to
page 2 by pressing the down-navigation button.
System and Tools Page 2

Viewing Your Speed-Filter Settings

The type of speed filter (narrow-band or wide-band) used by the APEX is set at the
factory, and depends on the type of application you are running—conveyor, gravity-feed,
pipeline, or pharmaceutical. The screen below shows the narrow-band filter, which is
used by conveyor and gravity-feed applications, and is the default setting. Please note
that if you are running a pipeline or pharmaceutical application, this screen will show the
wide-band filter (the default setting).
Speed Filter
Calibrating the Speed Filter
The speed-filter calibration process differs, depending on which type of application you
are running—conveyor, gravity-feed, pipeline, or pharmaceutical.
1) Make sure the speed-filter menu is highlighted.
Speed Filter
Page 170
Thermo Scientific APEX User's Guide