Configuring Inclusion of the Sending Complete
Information Element
In some geographic locations, such as Hong Kong and Taiwan, ISDN switches
require that the Sending Complete information element be included in the
outgoing Setup message to indicate that the entire number is included.
This information element is generally not required in other locations.
To configure the interface to include the Sending Complete information
element in the outgoing call Setup message, use the following command in
interface configuration mode:
Step
1
configure terminal
2
Interface bundle
bundle-name
3
Link [pri_t1|pri_e1]
0/0/0:1
4
isdn
5
Switch-type switch-type
6
Incoming-voice
7
Sendling-complete
8
activate
Monitoring and Maintaining ISDN Interfaces
Command
Show isdn
interface WORD
© SAMSUNG Electronics Co., Ltd.
Command
Configures to set up bundle.
Sets up bundle name.
Sets up the pertinent physical link.
Sets up ISDN
Sets up the pertinent switch-type with the
content like the following table.
Sets up for voice.
Includes the Sending Complete information
element in the outgoing call Setup message...
Activates ISDN.
Displays the ISDN interface information
v239# show isdn interface
bundle prie2
------------
status
links in the bundle are down
number of links
total bandwidth
link restoral type
link restoral time
Ubigate iBG3026 Configuration Guide/Ed.00
Purpose
Purpose
down, all
2
128 kbps
automatic
10
555