Samsung Ubigate iBG3026 Configuration Manual page 577

Hide thumbs Also See for Ubigate iBG3026:
Table of Contents

Advertisement

Address Signaling
Is in compliance with ITU-T Q.316~Q.326 recommendation.
Signals
KP(start-of-pulsing)
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
Digit 6
Digit 7
Configure T1-CAS E&M signaling
Step
1
2
3
4
5
6
7
© SAMSUNG Electronics Co., Ltd.
Frequencies(Hz)
1100 + 1700
700 + 900
700 + 1100
900 + 1100
700 + 1300
900 + 1300
1100 + 1300
700 + 1500
Command
configure terminal
module t1 slot/sub-
slot/port
cas-ds0-group ds0-
group-no
exit
voice-port slot/sub-
slot/port:ds0-group-
no
shutdown
timeslots timeslot-
list
Ubigate iBG3026 Configuration Guide/Ed.00
Signals
Digit 8
Digit 9
Digit 0
SP(end-of-pulsing)
spare
spare
spare
-
Purpose
Enter the global configuration mode.
Enter the module configuration mode.
Enter the ds0-group number to create in this E1
trunk.
Exits the module configuration mode.
To set up the attribute values of created ds0-group,
enter voice-port configuration mode.
if ds0-group was created normally, there is no error
in this CLI command.
Shuts down the voice port to manipulate 'timeslots'
and 'signal cas' command.
timeslots-Specifies the single time slot number,
single range of numbers, or multiple ranges of
numbers separated by commas. For T1, allowable
values are from 1 to 24.
Examples are as follows:
-2, 3-5
-1, 7, 9
-1-12
Frequencies(Hz)
900 + 1500
1100 + 1500
1300 + 1500
1500 + 1700
700 + 1700
900 + 1700
1300 + 1700
-
535

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents