4 Operation and Configuration
Calibrate
Printing > Advanced > Calibrate
Adjust the media sensor level.
In instances of media detection malfunction, adjust the media sensor level
(Gap and I-mark sensor).
The setting items are as follows:
1
Auto-calibration
2
GAP Levels
3
GAP Slice Level
4
I-Mark Levels
5
I-Mark Slice Level
Auto-calibration
Printing > Advanced > Calibrate > Auto-calibration
Perform the auto-calibration for the selected media sensor.
• Gap + I-Mark: Perform the adjustment for both the Gap sensor and I-
mark sensor.
• Gap: Perform the adjustment for the Gap sensor.
• I-Mark: Perform the adjustment for the I-mark sensor.
Procedures:
1. Pass the media below the media sensor guide. If you are using labels,
remove the label from the liner. Align it so that the media sensor does
not sense the I-mark (black mark).
2. Close the print head. To get the correct adjustment result, adjust after
you have closed the print head.
/
3. Press the
adjusted.
4. Press the right soft button or the
ment.
5. The sensor adjustment result shows. To exit the adjustment, press the
right soft button.
6. Set to offline mode. Press the right soft button to confirm that the
media feeds correctly.
Note:
If the media does not feed correctly after Auto-calibration, contact your
SATO reseller or technical support center.
76
CL4NX Operator Manual
Automatically adjust the sensor level.
Manually set the Gap sensor level.
Manually set the Gap sensor slice level.
Manually set the I-mark sensor level.
Manually set the I-mark sensor slice level.
arrow buttons to select the type of sensor to be
button to start the sensor adjust-