Global Error Indicator; Locating The Defective Component; Local Diagnostic Indicators On The Front - Fujitsu PRIMERGY CX400 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY CX400 M4:
Table of Contents

Advertisement

4.1.2.2

Global Error indicator

Ê Check the Global Error indicator on the front or connector panel of the server
(see section
"Controls and indicators" on page
Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in the "Upgrade and
Maintenance Manual" of the related server node.
– Software/agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.3

Locating the defective component

After determining the error class by the CSS or Global Error indicators (see
section
"Determining the error class" on page
the system board, HDD modules and PSUs (only slide-in units) allow you to
identify the defective component.
I
For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual.
4.1.3.1

Local diagnostic indicators on the front

Ê Check the CSS indicator on the front panel of the server enclosure or rear
connector panel on the server.
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit (see section
CX400 M4
"Determining the error class" on page
Upgrade and Maintenance Manual
Basic hardware procedures
183).
38) local diagnostic indicators on
38).
39

Hide quick links:

Advertisement

Table of Contents
loading