Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL), see section
page
86.
– Software/agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For more information, see the "ServerView System Monitor" user
guide.
4.1.3

Locating the defective component

After determining the error class by the CSS or Global Error indicators (see
section
"Determining the error class" on page
the front panel and system board allow you to identify the defective component.
I
For more information, see the "ServerView Suite Local Service Concept
(LSC)" manual.
4.1.3.1

Local diagnostic indicators on the front

Ê Check the CSS indicator (see section
page
391) on the front panel or I/O panel of the server.
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit.
4.1.3.2

Local diagnostic indicators on the system board

Using the Indicate CSS button
Ê Shut down and turn off the server.
Ê Disconnect the AC power cord(s) from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
CSS functionality.
RX2520 M4
Upgrade and Maintenance Manual
Basic hardware procedures
"Viewing the SEL" on
46) local diagnostic indicators on
"Connectors and indicators" on
47