power-save-dos-min-frames
power-save-dos-quiet-time
power-save-dos-threshold
probe-request-rate-thresholds <number>
probe-response-rate-thresholds <number>
rts-rate-quiet-time
rts-rate-threshold
rts-rate-time-interval
spoofed-deauth-blacklist
tkip-replay-quiet-time
Description
This command configures traffic anomalies for denial of service (DoS) attacks.
Syntax
Parameter
<profile>
ap-flood-inc-time
ap-flood-quiet-time
ap-flood-threshold
assoc-rate-thresholds
auth-rate-thresholds
block-ack-dos-quiet-time
chopchop-quiet-time
client-ht-40mhz-intol-quiet-
time <seconds>
client-flood-inc-time
client-flood-quiet-time
client-flood-threshold
282 | ids dos-profile
Description
Name that identifies an instance of the
profile. The name must be 1-63 characters.
Time, in seconds, during which a configured
number of fake AP beacons must be
received to trigger an alarm.
After an alarm has been triggered by a fake
AP flood, the time, in seconds, that must
elapse before an identical alarm may be
triggered.
Number of fake AP beacons that must be
received within the flood increase time to
trigger an alarm.
Rate threshold for associate request frames.
Rate threshold for authenticate frames.
Time to wait, in seconds, after detecting an
attempt to reset the receive window using a
forged block ACK add.
Time to wait, in seconds, after detecting a
ChopChop attack after which the check can
be resumed.
Controls the quiet time (when to stop
reporting intolerant STAs if they have not
been detected), in seconds, for detection of
802.11n 40 MHz intolerance setting.
Number of consecutive seconds over which
the client count is more than the threshold.
Time to wait, in seconds, after detecting a
client flood before continuing the check.
Threshold for the number of spurious clients
Dell PowerConnect W-Series ArubaOS 6.2 | Reference Guide
Range
Default
"default"
0-36000
3600
seconds
60-360000
900
seconds
0-100,000
50
60-360000
900
seconds
seconds
60-360000
900
seconds
seconds
60-360000
900
seconds
seconds
0-36000
3 seconds
seconds
60-360000
900
seconds
seconds
0-100000
150