Troubleshooting
Other Messages
Initialization Complete--Fatal Error.
Possible Cause
Feature button has failed
on-line verification during
initialization.
The CMS card is not
found.
Press F8.
Corrective Action
1. Press [F8] to display CMS menu.
2. Use centralized telephone programming
to remove this assignment from button
34 on the CMS supervisor telephone.
3. Program a new Feature button.
1. Press [F8] to display the CMS Menu.
2. Stop the program (Exit to DOS).
3. Turn off the PC.
4. Determine whether the CMS card is in
place and properly configured. (See Iin-
stallation and Programming Guide.)
Other Messages 9-17