Rmon Alarm - Dell PowerConnect 8024 Cli Reference Manual

Cli reference guide
Hide thumbs Also See for PowerConnect 8024:
Table of Contents

Advertisement

RMON Commands
This chapter explains the following commands:

rmon alarm

rmon collection history
rmon event
show rmon alarm
show rmon alarm-table
show rmon collection history
show rmon events
show rmon history
show rmon log
show rmon statistics
rmon alarm
Use the rmon alarm command in Global Configuration mode to configure alarm conditions. To
remove an alarm, use the no form of this command. Also see the related show rmon alarm
command.
Syntax
index variable interval rthreshold fthreshold revent fevent
rmon alarm
direction
name
] [owner
index
no rmon alarm
index — The alarm index. (Range: 1–65535)
variable — A fully qualified SNMP object identifier that resolves to a particular instance of an
MIB object.
interval — The interval in seconds over which the data is sampled and compared with the
rising and falling thresholds. (Range: 1–4294967295)
rthreshold — Rising Threshold. (Range: 0–4294967295)
fthreshold — Falling Threshold. (Range: 0–4294967295)
]
type
[type
] [startup
RMON Commands