revent — The index of the Event that is used when a rising threshold is crossed. (Range: 1-
65535)
fevent — The Event index used when a falling threshold is crossed. (Range: 1- 65535)
type — The sampling method for the selected variable and calculating the value to be
type
compared against the thresholds. If the method is absolute, the value of the selected variable
is compared directly with the thresholds at the end of the sampling interval. If the method is
delta, the selected variable value at the last sample is subtracted from the current value, and
the difference compared with the thresholds.
startup
sample (after this entry becomes valid) is greater than or equal to the
direction is equal to rising or rising-falling, then a single rising alarm is generated. If the first
sample (after this entry becomes valid) is less than or equal to the
equal to falling or rising-falling, then a single falling alarm is generated.
owner
name is an empty string.
Default Configuration
The following parameters have the following default values:
type — If unspecified, the type is absolute.
type
startup
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
The following example configures the following alarm conditions:
Alarm index — 1
Variable identifier — 1.3.6.1.2.1.2.2.1.10.5
Sample interval — 10 seconds
Rising threshold — 500000
Falling threshold — 10
Rising threshold event index — 1
Falling threshold event index — 1
976
RMON Commands
direction — The alarm that may be sent when this entry is first set to valid. If the first
name — Enter a name that specifies who configured this alarm. If unspecified, the
direction — If unspecified, the startup direction is rising-falling.
rthreshold , and
fthreshold , and direction is