Section 6: Reading buffers
Command
Commands to store readings
smuX.measure.count = count
smuX.measure.overlappedi(rbuffer)
smuX.measure.overlappediv(ibuffer,
vbuffer)
smuX.measure.overlappedp(rbuffer)
smuX.measure.overlappedr(rbuffer)
smuX.measure.overlappedv(rbuffer)
smuX.measure.v(rbuffer)
smuX.measure.i(rbuffer)
smuX.measure.iv(ibuffer, vbuffer)
smuX.measure.r(rbuffer)
smuX.measure.p(rbuffer)
smuX.trigger.measure.v(rbuffer)
smuX.trigger.measure.i(rbuffer)
smuX.trigger.measure.r(rbuffer)
smuX.trigger.measure.p(rbuffer)
smuX.trigger.measure.iv(ibuffer,
vbuffer)
Command
Commands to access readings
printbuffer(start_index, end_index,
st_1, st_2, ... st_n)
* smuX can be smua for channel A or smub for channel B
6-8
Model 2606B System SourceMeter® Instrument Reference Manual
Description
The number of measurements to acquire.
Makes current measurements; stores readings in
rbuffer.
Makes both current and voltage measurements; stores
current readings in ibuffer and stores voltage
readings in vbuffer.
Makes power measurements; stores readings in
rbuffer.
Makes resistance measurements; stores readings in
rbuffer.
Makes overlapped voltage measurements; stores
readings in rbuffer.
Makes voltage measurements; stores readings in
rbuffer.
Makes current measurements; stores readings in
rbuffer.
Makes both current and voltage measurements; stores
current readings in ibuffer and stores voltage
readings in vbuffer.
Makes resistance measurements; stores readings in
rbuffer.
Makes power measurements; stores readings in
rbuffer.
Configures voltage measurements to be made during a
sweep, including where readings are stored (rbuffer).
Configures current measurements to be made during a
sweep, including where readings are stored (rbuffer).
Configures resistance measurements to be made during
a sweep, including where readings are stored
(rbuffer).
Configures power measurements to be made during a
sweep, including where readings are stored (rbuffer).
Configures both current and voltage measurements to be
made during a sweep, including where readings are
stored; current readings are stored in ibuffer and
voltage readings are stored in vbuffer.
Description
Prints data from buffer subtables:
start_index (starting index of values to print)
end_index (ending index of values to print)
st_1, st_2, ... st_n (subtables from which to
print, each separated by a comma)
2606B-901-01 Rev. C November 2021