Example:
SN60023 > sysNodeNameModeShow
Active system node name mode is 0
Mode 0: Node name is the same on all FC Interfaces
Mode 1: Node name is based on port name, but different from port
name
value = 0 = 0x0
SN60023 >
sysVpdShow or sysVpdShowAll
The sysVpdShow command displays Vital Product data information. The Vital Product
Data for the SNC includes such items as serial numbers and installed memory sizes, as
shown below.
SN60023 > sysVpdShow
******** VPD Base Rev. 1 ********
Name
Mfg
ADIC
OEM
Manufacture Date JUN 13 05:19:59 1974
UID
S/N
Assy HCO
RID Tag
Firmware ID
FirmwareVend
Firmware Version 4.01
Config File Sys /nvfs
Code File Sys
A Board Name
A Board S/N
A Board HCO
B Board Name
B Board S/N
B Board HCO
value = 0 = 0x0
SN60023 >
The sysVpdShowAll shows a little more information and includes product data for the
Fibre Channel GBIC.
sysVpdShow or sysVpdShowAll
SNC
ADIC
00:00:00:60:45:17:00:17
600023
BKA01001P
Firmware-4
ADIC
/ffs
ADIC SNC
BK001120P
B Board Proc
BK002100P