ADIC Scalar 100 User Manual page 200

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

Table B-2: Environmental Channels
Channel Name
Fan
SN60023 > envMonShow
Channel
------------------------------------------------------
Air Inlet Temperature
Air Outlet Temperature
IO Processor Temperature
Input Power:
Input Power:
Local Power
Local Power
Local Power
All Power
All Temp
Sample Count
value = 1 = 0x1
envMonRangeShow
The envMonRangeShow command specifies operational ranges for the SNC's
environmental channels. It displays ranges of values associated with the Nominal,
Warning, and Alarm states for voltage, temperature, and fan/blower operation according
to the channels defined in the envMonShow command:
SN600012 > envMonRangeShow
Air Inlet Temp (C):
Air Outlet Temp (C):
page 186
Fan running (for tachometer fans:
RPM of fan)
State
Value
Nominal
Nominal
5 Volts
Nominal
12 Volts
Nominal
2.5 Volts
Nominal
3.3 Volts
Nominal
3.3 Volts Aux Nominal
Nominal
Nominal
20
Nominal: 5 to 45
Warning: 4 <= N < 5 or 45 < N <= 50
Alarm:
N < 4 or N > 50
Nominal: 5 to 50
Warning: 4 <= N < 5 or 50 < N <= 55
Alarm:
N < 4 or N > 55
Description
44 C
51 C
Warning
31 C
5.2 V
12 V
3.3 V
3.3 V
3.29 V
envMonRangeShow

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snc 5101

Table of Contents