device.map restoring it for use when the SNC reboots. The normalBoot command
will then reboot the unit.
rdate
timeserver
"
"
The rdate " timeserver " command sets the system date and time to be read from a
remote system. The "setTimeHost" command on page 226 must already have been
entered before the rdate " timeserver " command is issued. To see data from the
new setting, use the date command. To set the date and time to be read from a remote
system named "Cronos," enter the following command:
SN60023 > rdate "Cronos"
value = 0 = 0x0
SN60023 >
reboot
The reboot command requests that the SNC shut down existing operations and then
restart. This is the preferred method of restarting the SNC. There are processes running
within the SNC that may have writes pending to files within the flash file system.
Following a reboot command, these processes flush their data to the flash file system, and
the flash file system writes all pending data out to the flash memory. Only after all pending
data has successfully been written to flash, will the SNC start a reset cycle.
SN60023 > reboot
reset
The reset command immediately initiates a reset cycle. Any pending data writes to the
flash file system will be lost. This operation is not typically used. The reboot command
should be used to gracefully shutdown and restart the SNC.
SN60023 > reset
ridtag [
value
]
"
"
The ridtag command is used to change the replacement identifier (RID) tag for the SNC
after it has been replaced by the service representative. This should be the final step after
replacing and verifying that the replacement unit is performing satisfactorily.
The sysVpdShow command will display the RID tag. Before replacing the SNC, you
must determine the existing RID tag, if there is one, or the original serial number if no
replacement has been made.
page 215
rdate "timeserver"