In the example, Channel Zoning was used for access control. Fibre Channel 1 has access
to all of the attached SCSI tape and disk devices. For the other Fibre Channel interface,
Channel Zoning has been setup to restrict access to certain devices.
SN60023 > fcShowDevs
FC 1:
LUN Chan Id Lun Vendor Product
-----------------------------------------------------
0 0 0 0 SNC 0338 00000060450d0080
17 3 0 0 OEM
18 3 0 1 OEM
19 3 1 0 OEM
6 1 1 0 OEM OEM DCHS04X
7 1 2 0 OEM OEM DCHS04X
8 2 3 0 OEM OEM DCHS04X
9 2 4 0 OEM OEM DCHS04X
FC 2:
LUN Chan Id Lun Vendor Product
-----------------------------------------------------
0 0 0 0 SNC 0338 00000060450d0080
8 2 3 0 OEM OEM DCHS04X
9 2 4 0 OEM OEM DCHS04X
value = 6 = 0x6
SN60023 >
fcShowNames
The fcShowNames command displays the node and port names (addresses) of the Fibre
Channels.
page 196
03570C12
03570C12
03570C12
Ctlr Id
Indicates the Channel Number for the interface
PCI Addr
The PCI address of the interface, showing bus, device id,
and function number.
ISPType
The type of Fibre Channel Controller, ISP2300.
Node Name
The Fibre Channel node name for the SNC.
Port Name
The Fibre Channel port name for the interface.
Rev SN
5346 000000000305
5346 000000000305
5346 000000000306
6363
681F775B
6363
682086D3
6363
6820837B
6363
682076AC
Rev SN
6363
6820837B
6363
682076AC
fcShowNames