11. From the service terminal, enter the ifShow command. See "Service Port Command
Reference" on page 171.
SN600752 > ifShow
ibmEmac (unit number 0):
Flags: (0x8063) UP BROADCAST MULTICAST ARP RUNNING
Type: ETHERNET_CSMACD
Internet address: 172.16.76.211
Broadcast address: 172.16.255.255
Netmask 0xffff0000 Subnetmask 0xffff0000
Ethernet address is 00:60:45:17:02:f0
Metric is 0
Maximum Transfer Unit size is 1500
114192 packets received; 364 packets sent
114023 multicast packets received
116 multicast packets sent
0 input errors; 0 output errors
0 collisions; 0 dropped
lo (unit number 0):
Flags: (0x8069) UP LOOPBACK MULTICAST ARP RUNNING
Type: SOFTWARE_LOOPBACK
Internet address: 127.0.0.1
Netmask 0xff000000 Subnetmask 0xff000000
Metric is 0
Maximum Transfer Unit size is 32768
0 packets received; 0 packets sent
0 multicast packets received
0 multicast packets sent
0 input errors; 0 output errors
0 collisions; 0 dropped
value = 29 = 0x1d
12. If there is no entry for ibmEmac, replace the SNC.
Go to "Preparing for Removal and Replacement of the SNC" on page 154.
Consult ADIC service personnel.
13. From the ifShow display, write down the values of the internet address, netmask,
and subnetmask.
14. Compare the internet address with the IP address supplied by the network
administrator.
Compare the netmask value with the netmask in hex format supplied by the network
administrator.
The subnetmask should be the same as the netmask. If these values are correct, go
to step 16.