The route command is invoked to add, remove, and list the route table.
route
The route " add " command adds a route to the destination through the gateway.
SN60023 > route "add","200.0.0","bruno"
SN60023 >
route
The route " delete " command removes a route to the destination through the
gateway.
SN60023 > route "delete","200.0.0","bruno"
SN60023 >
route
The route " list " command lists the existing routes.
SN60023 > route "list"
Destination SNC
-------------------- --------------------
socrates
Destination
-------------------- --------------------
200.0.0
value = 0 = 0x0
SN60023 >
rtcDateSet[year],[month],[dayofmonth],[dayofweek],
[hour],[minute],[second]
The rtcDateSet command allows you to set the date and time manually. You must use
a 24-hour clock. All parameters are digits. The year can be either two or four digits. Single
digit months or hours should not be filled out with leading zeroes. A digit from 1-7 needs
to be entered for the [dayofweek] parameter, but it doesn't matter what you enter, since
the command will automatically correct it if it is wrong. To display the new time and date
data after entering the rtcDateSet command, enter the date command. To set the
RTC to 9:35 A.M. on Friday, January 26, 2001, enter the following string:
SN60023 > rtcDateSet 2001,1,26,5,9,30,00
value = 0 = 0x0
SN60023 >
route "add","destination","gateway"
add
,
destination
"
"
"
delete
,
destination
"
"
"
list
"
"
bruno
SNC
bruno
Attention: The time will be one hour off when Daylight Savings Time is in
effect.
,
gateway
"
"
"
,
gateway
"
"
"
page 217