ADIC Scalar 100 User Manual page 176

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

Table 6-1: Post-Repair Checklist
Step
10
11
12
13
page 162
Actions
From the service
terminal, enter the
fcShow command to
show the status of each
FC interface that is
installed and connected.
From the service
terminal, enter the
fcShowDevs
command to show the
SCSI target devices that
are connected as seen by
the Fibre Channel
interface.
Verify that all (or the
designated) target
devices are available to
the host systems.
Disconnect the RS-232
cable from the SNC and
from the service
terminal.
End of repair.
Comments and References
In the output of the fcShow command, look for the
Firmware State column. If the word Ready does not
appear, go to "Fibre Channel MAP" on page 142.
Check to see that all SCSI target devices are seen by
each FC interface. If not, go to "SCSI MAP" on
page 134.
Use appropriate host system utilities for disk and tape.
If "Access Control" is enabled (Channel Zoning or
SFM) the hosts will only see the devices that have
been assigned to them.
If the designated devices are NOT available, reboot
the host and check again. If the problem persists, go to
"Start MAP" on page 129.
None.
Post-Repair Checklist

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snc 5101