Table 5-3: Service Reference Table
Event
Code
43
58
59
60
2
61
2
62
63
2
64
65
66
67
68
3
70
page 126
Default
Viewing
Trap
Level
Threshold
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Description
Fibre Channel interface driver
reported debug file dump (event log
contains further information)
Power has returned to Nominal
from Warning or Alarm Stage
Power has entered Warning Range
from Nominal Range (Power
falling) or Alarm Range (Power
improving)
Power has entered Alarm Range
Inlet Air, Outlet Air, or I/O
Processor temperatures have
entered Nominal Range from a
Warning or Alarm Range
Inlet Air Temperature has entered
Warning Range from Nominal
Range (heating up) or Alarm Range
(cooling down)
Inlet Air Temperature has entered
Alarm Range
Outlet Air Temperature or I/O
Processor Temperature has entered
Warning Range from Nominal or
Alarm Ranges
Outlet Air Temperature or I/O
Processor Temperature has entered
Alarm Range
Fan is operating in Nominal Range
after operating in a fault state
Fan speed has entered Warning
Range (Tachometer fans only)
Fan speed has entered Alarm Range
(Tachometer fans) or is stalled
(rotor stall fans)
Firmware upload completed
Action
13
0
5
5
0
4
4
4
4
0
4
4
0
Service Reference Table

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snc 5101