IO Processor Temp (C):
Input Power: +5 Volts (V):
Input Power: +12 Volts (V):
Local Power: +2.5 Volts (V):
Local Power: +3.3 Volts (V):
Local Power: +3.3 Volts Aux (V):
Fan :
Nominal: 1;
value = 1 = 0x1
SN600012 >
ethAddrGet
The ethAddrGet command displays the IP address of the Storage Networking
Controller, specified as 4 decimal numbers separated by periods.
SN60023 > ethAddrGet
IP Address set to 192.168.1.176
value = 0 = 0x0
SN60023 >
ethAddrGet
Nominal: 5 to 80
Warning: 4 <= N < 5 or 80 < N <= 108
Alarm:
N < 4 or N > 108
Nominal: 4.83 to 5.20
Warning: 4.75 <= N < 4.83 or 5.20 < N <= 5.25
Alarm:
N < 4.75 or N > 5.25
Nominal: 11.00 to 12.93
Warning: 10.75 <= N < 11.00 or 12.93 < N <= 13.18
Alarm:
N < 10.75 or N > 13.18
Nominal: 2.42 to 2.58
Warning: 2.36 <= N < 2.42 or 2.58 < N <= 2.62
Alarm:
N < 2.36 or N > 2.62
Nominal: 3.20 to 3.39
Warning: 3.13 <= N < 3.20 or 3.39 < N <= 3.46
Alarm:
N < 3.13 or N > 3.46
Nominal: 3.20 to 3.39
Warning: 3.13 <= N < 3.20 or 3.39 < N <= 3.46
Alarm:
N < 3.13 or N > 3.46