csClearLogFile
The csClearLogFile command clears the contents of the event log.
SN600726 > csClearLogFile
value = 0 = 0x0
SN600726 >
date
The date command displays the system's date and the time. The system may be set to
read its local Real Time Clock (see the dateSetFromRTC command) or a remote host
(see the rdate " timeserver " command). The local Real Time Clock can also be
synchronized with a remote timeserver (see the rtcSetCurrent command).
SN60023 > date
SN60023 > THU JAN 25 20:32:49 2001
SN60023 >
dateSetFromRTC
The dateSetFromRTC command sets the SNC's RTC as the source of the date display.
Use the date command to display the date and time.
SN60023 > dateSetFromRTC
value = 0 = 0x0
SN60023 >
diagBoot
This command is used only to transition the SNC from normal operation to the special
diagnostic mode. The diagBoot command first ensures that the ffs:mt directory exists. It
verifies that the files diagnstk.o and diagnstk.rc are in the flash file system. If they are in
the root directory, it moves them to the ffs:mt directory.
It copies the existing bootline to a file in the ffs:mt directory on the SNC and installs a new
bootline directing the SNC to boot using a special diagnostic startup script ffs:mt/
diagnstk.rc. It renames the persistent map file config/device.map as config/device.bak (a
new file will be generated after rebooting).
Finally, diagBoot issues a reboot command to put the changes into effect.
Attention: After completing use of the diagnostic commands, use the
normalBoot command to restore your system to normal operation.
page 183
csClearLogFile