2-42 TSP Programming Fundamentals
Table 2-3
Example interactive chunk fragment for a script
--Prompt operator to select channel:
--Prompt operator to select (input) the source function:
--Prompt operator to set (input) source level:
--Wait for operator to set source level:
2600S-901-01 Rev. A / May 2006
Script Chunk Fragment (Test Script Builder or User's Program)
chan = display.menu ("Select Channel", "smua smub")
if (chan == "smua") then
chan = smua
end
if (chan == "smub") then
chan = smub
end
func = display.menu("Select Function", "amps volts")
if (func == "amps") then
chan.source.func = chan.OUTPUT_DCAMPS
else chan.source.func = chan.OUTPUT_DCVOLTS
end
if (func == "amps") then
level = display.prompt("0.0E+00"," mA", "Enter I level",
1E-3, 0.5E-3, 5E-3)
else
level = display.prompt("00.0", " V", "Enter V level",
1, 0.1, 10)
end
if (func == "amps") then
chan.source.leveli = level
else chan.source.levelv = level
end
Return to
Series 2600 System SourceMeters Reference Manual
Section 2 topics