CHAPTER 2 WIRING
CONTa Through: Sequence output signal (Reference value 91)
CONTb Through: Sequence output signal (Reference value 92)
CONTc Through: Sequence output signal (Reference value 93)
CONTd Through: Sequence output signal (Reference value 94)
2
CONTe Through: Sequence output signal (Reference value 95)
This function allows communications input signals to be output via OUT signals of the hardware.
Function
The signals set to CONT 20 to 24 can be output through OUT signals 1 to 3 of the hardware. When
a CONT□ signal is allocated to an OUT signal, the ON/OFF status of the CONT signal is output
as a through signal to the OUT signal regardless of the function allocation of the corresponding
CONT signal.
CONT signals respectively correspond to CONT a to e
CONTa
CONTb
CONTc
CONTd
CONTe
Parameter setting
To assign a CONT□ through signal to a sequence output terminal, set the values (91 to 95)
corresponds to the parameter of output terminal function setting. The setting values to the relevant
signals are as follows.
PA3_51 to 53
No.
51
52
53
54
55
2-104
Description of I/O Signals
Corresponding CONT signals
CONT20
CONT21
CONT22
CONT23
CONT24
Name
OUT1 signal assignment
OUT2 signal assignment
OUT3 signal assignment
OUT4 signal assignment
OUT5 signal assignment
Setting range
0 to 95 91 : CONTa through
92 : CONTb through
93 : CONTc through
94 : CONTd through
95 : CONTe through
Change