CHAPTER 2 WIRING
 Parameter setting
To assign the command position completion to a sequence output terminal, specify the
corresponding value ("82") to the output terminal function setting parameter.

Range 1 of position: Sequence output signal (Reference value 83)

2

Range 2 of position: Sequence output signal (Reference value 84)

This signal is issued upon detection of the current servomotor position.
 Parameter setting
The signal can be output at two positions: position range 1 and 2.
Range 1 of position: Enter at PA3_92 and _93.
Range 2 of position: Enter at PA3_94 and _95.
1) Setting value of PA3_92 < Setting value of PA3_93
Range1 of position: Setting1 (PA3_92)
Motor current
position
Range1 of
position
2) Setting value of PA3_92 > Setting value of PA3_93
Range1 of position: Setting2 (PA3_93)
Motor current
position
Range1 of
position
Note: If setting 1 of range 1 of position (PA3_92) is the same as setting 2 of range 1 of
position (PA2_93), range 1 of position is always turned off. The same is true for range 2 of
position.
2-100
Description of I/O Signals
1000.00
OFF
ON
1000.00
ON
OFF
Range1 of position: Setting2 (PA3_93)
3000.00
OFF
Range1 of position: Setting1 (PA3_92)
3000.00
ON