3.2 Selection of Operation Procedure

The VV type servo amplifier is capable of speed control and torque control with analog voltages,
position control with pulse, positioning data operation with Di/Do signals or RS-485 communications,
and immediate value data operation with RS-485 communications.
Follow the flow chart below to select the desired operation and enter parameters, etc.
START
No
Positioning operation
with amplifier alone?
Yes
Enter "7" to PA1_01
(control mode selection).
Positioning operation
with internal data?
Yes
Enter "1" to PA2_40
(internal positioning data selection).
Positioning operation for up to 31
points can be made according to
internal data.
Refer to pages 3-16
and 3-17.
No
Immediate value positioning
operation is necessary.
Enter "0" to PA2_40
(internal positioning data selection).
Positioning operation can be made
according to RS-485 (Modbus-RTU or PC
Loader) communications.
Refer to pages 3-16
and 3-21.
③④
CHAPTER 3 OPERATION
No
Operation in FALDIC-α
series-compatible mode?
Yes
Enter "6" to PA1_01
(control mode selection).
Operation can be made with the
same host settings as those of
FALDIC-α Series.
Refer to pages 3-13
through 3-17.
(Immediate value data +
startup command)
Selection of Operation Procedure
Positioning control with
speed control, torque control
or pulse is used.
Enter "1" to "5" to PA1_01
(control mode selection).
Operation can be made
according to analog voltages
and pulse commands.
Refer to pages 3-9
through 3-12.
3-3