6.4 Monitor Mode

In the monitor mode, the servomotor rotation speed, cumulative input pulse and so on are displayed.
Press the [MODE/ESC] key until [
least one second to display data.
: Feedback speed
on_01
: Command speed
on_02
: Command torque
on_03
: Motor current
on_04
: Peak torque
on_05
: Effective torque
on_06
: Feedback position
on_07
: Command position
on_08
: Position deviation
on_09
: Command pulse
on_10
frequency
(1) Feedback speed (displayed digits: signed four digits)
Current rotation speed of servomotor.
The correct value is displayed even if the load (mechanical system) rotates the motor.
The speed is displayed in [r/min] and a negative sign is attached for reverse rotation (clockwise
rotation when viewed against the motor shaft).
on_01
SET
SET
ESC
(1秒以上)
ESC
(1 sec. or over)
-6000
on_0n
] is displayed, and press and hold the [SET/SHIFT] key for at
on_11
: Feedback cumulative
pulse
on_12
: Command cumulative
pulse
: LS-Z pulse
on_13
on_14
: Load inertia ratio
on_15
: DC link voltage (max.)
on_16
: DC link voltage (min.)
on_17
: VREF input voltage
on_18
: TREF input voltage
on_19
: Input signal
on_20
: Output signal
CHAPTER 6 KEYPAD
on_21
: OL thermal value
on_22
: Regenerative resistor thermal
value
on_23
: Power (W)
on_24
: Motor temperature
on_25
: Overshoot unit amount
on_26
: Settling time
on_27
: Resonance frequency 1
on_28
: Resonance frequency 2
Monitor Mode
6
4
6-15