PA2_89 and 90 Sequence test mode: Mode selection and encoder selection

No.
Name
Sequence test mode:
89
Mode selection
Sequence test mode:
90
Encoder selection
PA2_89 (sequence test mode):
Select 0 to start the sequence test mode from the PC Loader or keypad. Turn the power off
then on again to return to the normal mode.
Specify the encoder bit according to the type of the servomotor.
PA2_89 (sequence test mode):
Select 1 to always start the sequence test mode. To return to the normal mode, change
PA2_89 to 0 and turn the power off then on again.
Specify the encoder bit according to the type of the servomotor.
In sequence test mode, the servo amplifier keypad flashes (once every 2 seconds.)
PA2_90: Specify the parameter according to the connected motor encoder bit.
* Sequence test mode does not support the safety option (WSU-ST1) function.

PA2_93 Parity/stop bit selection (for Modbus)

No.
Name
93
Parity/stop bit selection
Set existence and logic of a parity and a stop bit length.
Characters are organized for each setting as follows:
LSB
PA2_93
0
1
0, 1
Start
2
Start
3, 4
Start
5
Start
Setting range
0: Normal mode
1: Sequence test mode
4: 24 bit
0: Even parity with 1 stop bit
1: Odd parity with 1 stop bit
2: No parity with 1 stop bit
3: Even parity with 2 stop bits
4: Odd parity with 2 stop bits
5: No parity with 2 stop bits
2
3
4
5
Data (8 bits)
Data (8 bits)
Data (8 bits)
Data (8 bits)
Extended Function Setting Parameters
CHAPTER 4 PARAMETER
Setting range
6
7
8
9
Parity Stop
Stop
Parity Stop (2 bits)
Stop (2 bits)
Default
Change
value
0
Power
4
Power
Default
Change
value
0
Power
MSB
10
11
4-95
4