CHAPTER 4 PARAMETER
PA2_94 Response time (for Modbus)
PA2_95 Communication time over time (for Modbus)
No.
94
Response time
95
Communication time over
Enter the response time of the servo amplifier.
Enter the response time and communication time-over time when necessary.
For details, refer to "CHAPTER 13
4
PA2_97 Communication protocol selection
No.
Communication protocol
97
selection
Select either the PC Loader protocol or Modbus RTU communications.
The factory shipment setting is "0" (PC Loader protocol). To use Modbus RTU communications, do not
fail to change to "1."
4-96
Extended Function Setting Parameters
Name
0.00 to 1.00 [s]
0.00 [s]...No detection
0.01 to 9.99 [s]
MODBUS RTU COMMUNICATION"
Name
0: PC Loader protocol
1: Modbus RTU
Setting range
Setting range
Default
Change
value
0.00
Always
0.00
Always
Default
Change
value
0
Always