Pa3_72 Out Signal Inversion; Pa3_99 Out Fz Signal Inversion - Fuji Electric Alpha7 VV User Manual

Hide thumbs Also See for Alpha7 VV:
Table of Contents

Advertisement

CHAPTER 4 PARAMETER
PA3_72
PA3_99
No.
72
OUT signal inversion
99
OUT FZ signal inversion
Set if wishing to invert the status (ON/OFF) of signals output from sequence output terminal (OUT1 to
4
OUT5, OUT FZ).
Parameter PA3_72 (OUT signal inversion) selects functions for each digit for OUT1 to OUT5.
By setting 1 for each digit, the output signal logic is reversed.
4-112
Output Terminal Function Setting Parameters
OUT signal inversion
OUT FZ signal inversion
Name
00000 to 11111
0: No inversion, 1: Inversion
5
4
3
Digit
Setting range
2
1
OUT1 signal inversion
0: Do not invert
1: Invert
OUT2 signal inversion
0: Do not invert
1: Invert
OUT3 signal inversion
0: Do not invert
1: Invert
OUT4 signal inversion
0: Do not invert
1: Invert
OUT5 signal inversion
0: Do not invert
1: Invert
Default
Change
value
Power
00000
supply
Power
0
supply