CHAPTER 2 WIRING
Life warning: Sequence output signal (Reference value 46)
The life of internal main circuit capacitors of the servo amplifier and that of the cooling fan are
calculated and output its signal.
Function
2
The life of internal main circuit capacitors of the servo amplifier and that of the cooling fan are
calculated and, if either exceeds the rated time, a life warning is turned on.
Use the PC Loader or keypad (En_003) to discriminate between the main circuit capacitors and
cooling fan.
Parameter setting
To assign the life warning to a sequence output terminal, specify the corresponding value ("46") to
the output terminal function setting parameter.
MD0: Sequence output signal (Reference value 60)
MD1: Sequence output signal (Reference value 61)
MD2: Sequence output signal (Reference value 62)
MD3: Sequence output signal (Reference value 63)
MD4: Sequence output signal (Reference value 64)
MD5: Sequence output signal (Reference value 65)
MD6: Sequence output signal (Reference value 66)
MD7: Sequence output signal (Reference value 67)
The M code of positioning data currently executed is output.
Function
Positioning data M codes are output as is during execution.
Unlike JIS B 3614, there are no specific functions for M00, M02, M30, M98, or M99, and all codes
output are general-purpose codes.
There are no interlock functions such as MON or MOFF.
M codes are hexadecimal from 00 to FFH.
The default value M code output value is FFH (MD0 to MD are all ON).
Parameter setting
If assigning MD0 to the a sequence output terminal, set the value (60) corresponding to the output
terminal function setting parameter.
2-94