Interrupt Positioning Detection: Sequence Output Signal (Reference Value 85) - Fuji Electric Alpha7 VV User Manual

Hide thumbs Also See for Alpha7 VV:
Table of Contents

Advertisement

 Parameter setting
To assign range 1 or 2 of position to a sequence output terminal, specify the corresponding value
("83") or ("84") to the output terminal function setting parameter.

Interrupt positioning detection: Sequence output signal (Reference value 85)

This signal outputs the interrupt positioning motion mode status.
 Function
The signal turns on during interrupt positioning motion, and turns off with any of the following
conditions.
(1)
When the interrupt input enabling signal is turned off after the positioning motion completion.
FWD(REV)
Interrupt input
enable
Interrupt input
Interrupt positioning
detection
In-position
(2)
When the next start signal (FWD, REV, START, or ORG) is turned on.
FWD(REV)
Interrupt input
enable
Interrupt input
Interrupt positioning
detection
In-position
(3)
When the positioning cancel signal is turned on during interrupt positioning motion.
Speed
ON
OFF
OFF
OFF
OFF
ON
OFF
The interrupt positioning detection will not turn off even when
the interrupt input enabling signal is turned off during the
interrupt positioning motion.
The interrupt positioning detection will turn off if the interrupt input enabling signal is
turned off after the interrupt positioning completion (in-position = ON).
Speed
ON
OFF
Always ON
OFF
OFF
ON
OFF
CHAPTER 2 WIRING
PA2_20
(interrupt
traveling unit
amount)
Time
ON
ON
OFF
ON
ON
ON
PA2_20
(interrupt
traveling unit
amount)
OFF
ON
ON
ON
Description of I/O Signals
2
Time
ON
2-101