CHAPTER 2 WIRING
Output at completion (after completion)
M codes are output when the positioning operation is complete and then held.
Simultaneous M code simultaneous
2
Rotation speed
Operation prep.
complete [RDY]
Auto start
AD4 to AD0
Positioning
complete (level)
M code

Position preset completion: Sequence output signal (Reference value 75)

The signal is output after position preset (position change) is executed and completed.
 Function
If position preset is executed in an established ABS system (absolute system) to reset from an
alarm or change the current position, the sequence output corresponding to position preset
completion is turned on after position preset is finished.
 Parameter setting
To assign the position preset completion to a sequence output terminal, specify the corresponding
value ("75") to the output terminal function setting parameter.
2-96
Description of I/O Signals
OFF
ON
5
15
ON
OFF
FF
* Positioning data is executed while the timer time is counting up.
* The default M code is FF.
M code 20
Timer time
(positioning data)
ON
ON
20
Time