PXZ QUICK REFERENCE
Primary Menu
Parameter
Range
ProG
oFF/rUn/HLd
P
0.0 - 999.9%FS
I
0 - 3200sec
D
0.0 - 999.9sec
AL
0 - 100%FS
AH
0 - 100%FS
TC
1 - 150sec
HYS
0 - 50%FS
Hb
0.0 - 50.0A
AT
0 - 2
TC2
1 - 150sec
CooL
0.0 - 100.0
db
-50.0 - 50.0% FS Deadband/Overlap
PLC1
-
PHC1 -
PCUT -
bAL
0 - 100%
Ar
0 - 100%FS
LoC
0 - 2
STAT
--
SV-1
0 - 100%FS
TM1r 0 - 99hr 59min
TM1S 0 - 99hr 59min
SV-2
0 - 100%FS
TM2r 0 - 99hr 59min
TM2S 0 - 99hr 59min
SV-3
0 - 100%FS
TM3r 0 - 99hr 59min
TM3S 0 - 99hr 59min
SV-4
0 - 100%FS
TM4r 0 - 99hr 59min
TM4S 0 - 99hr 59min
MOD
0 -15
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Default
settings settings
Ramp/soak command
oFF
dSP1-1
Proportional band
5.0
dSP1-2
Integral time
240
dSP1-4
Derivative time
60
dSP1-8
Low Alarm Setpoint
10
dSP1-16
High Alarm Setpoint
10
dSP1-32
Cycle Time (output #1)
dSP1-64
Hysteresis
1
dSP1-128
Heater-break alarm S.P.
0.0
dSP2-1
Auto-tuning command
0
dSP2-2
Cycle Time (output #2)
dSP2-4
Proportional band
1.0
dSP2-8
coefficient for cooling
0.0
dSP2-16
N/A
-3.0
dSP2-32
N/A
103.0
dSP2-64
N/A
0
dSP2-128
Balance
0.0/50.0 dSP3-1
Anti-reset windup
100%FS dSP3-2
Lock out
0
dSP3-4
Ramp/soak status
oFF
dSP3-8
1st S.P.
0%FS dSP3-16
1st ramping time
0.00
dSP3-32
1st soaking time
0.00
dSP3-64
2nd S.P.
0%FS dSP3-128
2nd ramping time
0.00
dSP4-1
2nd soaking time
0.00
dSP4-2
3rd S.P.
0%FS
dSP4-4
3rd ramping time
0.00
dSP4-8
3rd soaking time
0.00
dSP4-16
4th S.P.
0%FS dSP4-32
4th ramping time
0.00
dSP4-64
4th soaking time
0.00
dSP4-128
Ramp/Soak Mode code
0
dSP5-1
PXZ QUICK REFERENCE
Secondary Menu
DSP
Parameter
P-n1
P-n2
P-dF
0.0 - 900.0sec
P-SL
P-SU
P-AL
P-AH
P-An
P-dP
rCJ
PVOF
SVOF
P-F
PLC2
PHC2
FUZY
GAIN
ADJO
ADJS
OUT
dSP1-7
† Based on the model
22
Range
Description
0 -19
Control Action code
0 - 16
Input type code
Input filter constant
-1999 - 9999
Lower range of input
-1999 - 9999
Upper range of input
0 - 15
Alarm Type 2 code
0 - 11
Alarm Type 1 code
0 - 50%FS
Alarm Hysteresis
0 - 2
Decimal point position
-
-
-10 - 10%FS
PV offset
-50 - 50%FS
SV offset
°C/°F
°C/°F Selection
-
N/A
-
N/A
OFF/ON
Fuzzy control
-
N/A
-
Zero calibration
-
Span calibration
-
N/A
0-255
Parameter mask
Default
DSP
settings settings
dSP5-4
dSP5-8
5.0
dSP5-16
0%FS dSP5-32
100%FS dSP5-64
9
dSP5-128
5
dSP6-1
1
dSP6-2
0
dSP6-4
ON
dSP6-8
0
dSP6-16
0
dSP6-32
dSP6-64
-3.0
dSP6-128
103.0
dSP7-1
OFF
dSP7-2
1
dSP7-4
0
dSP7-8
0
dSP7-16
-3.0
dSP7-32
-

Hide quick links: