Multi-Step Speed Selection [X1]: Sequence Input Signal (Reference Value 51); Multi-Step Speed Selection [X2]: Sequence Input Signal (Reference Value 52); Multi-Step Speed Selection [X3]: Sequence Input Signal (Reference Value 53) - Fuji Electric Alpha7 VV User Manual

Hide thumbs Also See for Alpha7 VV:
Table of Contents

Advertisement

Multi-step speed selection [X1]: Sequence input signal (Reference value 51)

Multi-step speed selection [X2]: Sequence input signal (Reference value 52)

Multi-step speed selection [X3]: Sequence input signal (Reference value 53)

Select the manual feed speed when in position control mode or speed control mode. This is used to
select the speed limit value when in torque control mode.
 Function
The rotation speed while the forward command [FWD] (reverse command [REV]) signal is turned
on is selected.
When in torque control mode, the servomotor rotation speed is limited to the selected speed.
Select the speed with multi-step speed [X1], [X2] or [X3].
The setting speed is shown in the table below.
X3
X2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
 Parameter setting
To assign the multi-step speed selection to a sequence input terminal, specify the corresponding
value ("51", "52" and "53") to the input terminal function setting parameter.
These signals are handled to be always turned off if they are not assigned to sequence input
terminals.
Parameter
X1
No.
OFF
-
Speed command terminal (VREF) voltage
ON
PA1_41
Manual feed speed 1/torque control speed limit 1
OFF
PA1_42
Manual feed speed 2/torque control speed limit 2
ON
PA1_43
Manual feed speed 3/torque control speed limit 3
OFF
PA1_44
Manual feed speed 4/torque control speed limit 4
ON
PA1_45
Manual feed speed 5/torque control speed limit 5
OFF
PA1_46
Manual feed speed 6/torque control speed limit 6
ON
PA1_47
Manual feed speed 7/torque control speed limit 7
CHAPTER 2 WIRING
Rotation speed for enabling
Description of I/O Signals