Edit Permission: Sequence Input Signal (Reference Value 55) - Fuji Electric Alpha7 VV User Manual

Hide thumbs Also See for Alpha7 VV:
Table of Contents

Advertisement

Edit permission: Sequence input signal (Reference value 55)

Editing operation for parameters and so on is limited with an external sequence input signal.
 Function
The edit permission assigned to a CONT input signal controls editing operation made at the
keypad or PC Loader.
The following operation can be executed only while the edit permission remains turned on.
 Parameter edit mode
 Positioning data edit mode
This function can be used to avoid inadvertent operation of the keypad or PC Loader, thereby
avoiding movement of the servomotor, drop of the machine, etc.
 Parameter setting
To assign the edit permission to a sequence input terminal, specify the corresponding value ("55")
to the input terminal function setting parameter.
 Relevant description
(1) Parameter write protection
Specify "1" (write protection) to PA2_74 (parameter write protection) to disable key operation at the
keypad and parameter editing at the PC Loader.
The relationship between the edit permission and PA2_74 (parameter write protection) is shown in
the table below.
Edit permission
Not assigned
OFF
ON
Not assigned
OFF
ON
(2) Edit permission response
The edit permission response is an output signal.
The signal is output if it is assigned to an output signal and the edit permission is turned on.
To assign the edit permission response to a sequence output terminal, specify the corresponding
value ("29") to the input terminal function setting parameter.
PA2_74
Parameter change operation
0 : Write enable
0 : Write enable
0 : Write enable
1: Write protect
1: Write protect
1: Write protect
CHAPTER 2 WIRING
Edit permission
response
ON
ON (Possible)
OFF
OFF (Impossible)
ON
ON (Possible)
OFF
OFF (Impossible)
OFF
OFF (Impossible)
OFF
OFF (Impossible)
Description of I/O Signals