Immediate value continuation permission: Sequence output signal (Reference value 79)
The signal is turned on when the system is ready to accept an immediate value continuation command.
 Function
The immediate value continuation command can be accepted only if this signal is turned on after
immediate data operation is started.
The signal is turned off after the continuation setting completion signal is turned on. It is turned on
again after data continuation is made.
The signal is turned off 50ms after positioning based on the post-continuation data.
For details, refer to "Immediate value continuation: Sequence input signal (Reference value 22)"
signal description.
 Parameter setting
To assign the immediate value continuation permission to a sequence output terminal, enter the
corresponding value ("79") to the output terminal function setting parameter. Relevant signal
reference values are shown below.
Immediate value continuation: sequence input signal
Immediate value continuation completion: sequence output signal
Immediate value continuation permission: sequence output signal
Assigned signal