CHAPTER 4 PARAMETER
PA2_80 to 85 Parameter in RAM 1 to 6
No.
80
Parameter in RAM 1
81
Parameter in RAM 2
82
Parameter in RAM 3
83
Parameter in RAM 4
84
Parameter in RAM 5
85
Parameter in RAM 6
If you change some parameters frequently, store them in RAM.
With this setting, you can change parameters infinitely.
4
Parameters that can be stored in RAM are those marked "Always" in the "Change" field.
The parameter stored in RAM is in the default value when the amplifier is turned on.
[Setting example] 1 to 99 = PA1_1 to 99, 101 to 199 = PA2_1 to 99, 201 to 299 = PA3_1 to 99, 301 to
399 = PA4_1 to 99

PA2_86 to 88 Positioning data in RAM 1 to 3

No.
86
Positioning data in RAM1
87
Positioning data in RAM2
88
Positioning data in RAM3
If you change positioning data frequently, store them in RAM.
With this setting, you can change positioning data infinitely.
The positioning data stored in RAM is in the default value when the amplifier is turned on.
4-94
Extended Function Setting Parameters
Name
0: No designation
1 to 399: Parameter No.
Name
0: No designation
1 to 15: Positioning data No.
Setting range
Setting range
Default
Change
value
0
Power
Default
Change
value
0
Power