PA2_16 Home position after homing completion

No.
Name
Home position after homing
16
completion
Not a compulsory item
Specify the coordinate position of the homing completion point.
After a homing is normally finished, the current position is
replaced with the reference value of this parameter.
Specify if the homing motion completion point is other than zero.

PA2_17 Home position detection range

No.
Name
Home position detection
17
range
Not a compulsory item
Specify the range in which the homing completion signal is turned on.
If the current position is between the positive home position detection range and negative home
position detection range around the home position, homing completion is turned on.
Specify 0 to always turn the homing completion signal on after a homing is finished.
Home position detection range
Homing completion
-OT
The zero position is not necessarily 0. The home position is the position specified as a home position
after homing completion (PA2_16) or preset position (PA2_19).
Setting range
-2000000000 to 2000000000
[unit amount]
Setting range
0: Always ON after homing completion
1 to 2000000000 [unit amount]
Home position detection range
OFF
ON
Home position
Automatic Operation Setting Parameters
CHAPTER 4 PARAMETER
Default
value
0
Home position shift unit amount
Home position
Reference signal for
shift operation
Home position after
homing completion
Default
value
0
OFF
+OT
Change
Always
4
Change
Always
4-51