Mccb/Elcb - Fuji Electric Alpha7 VV User Manual

Hide thumbs Also See for Alpha7 VV:
Table of Contents

Advertisement

CHAPTER 10 PERIPHERAL EQUIPMENT
10.3 MCCB/ELCB (Molded Case Circuit Breaker/Earth
Leakage Breaker)
Install MCCB (molded case circuit breaker) or ELCB (earth leakage breaker) in the primary circuit
(power supply circuit) of the servo amplifier to protect the servo amplifier against losses caused by the
power switching current and short circuit current. Models for a single servo amplifier are described
here. Because the servo amplifier is provided with protective functions against output circuits such as
the overcurrent, protective devices such as the thermal relay are unnecessary.
Model of molded case circuit breaker and earth leakage breaker
 In case of single-phase 200V
Servo amplifier
capacity [kW]
0.05
0.1
0.2
0.4
0.75
 In case of 3-phase 200V
Servo amplifier
capacity [kW]
0.05
0.1
0.2
10
0.4
0.75
1.0
1.5
10-8
MCCB/ELCB (Molded Case Circuit Breaker/Earth Leakage Breaker)
MCCB
BW32AAG-2P003
BW32AAG-2P005
BW32AAG-2P010
BW32AAG-2P015
MCCB
BW32AAG-3P003
BW32AAG-3P005
BW32AAG-3P010
BW32AAG-3P015
BW32AAG-3P020
ELCB
(Sensed current: 30mA)
EW32AAG-2P003
EW32AAG-2P005
EW32AAG-2P010
EW32AAG-2P015
ELCB
(Sensed current: 30mA)
EW32AAG-3P003
EW32AAG-3P005
EW32AAG-3P010
EW32AAG-3P015
EW32AAG-3P020