CHAPTER 1 INSTALLATION
1.2.2 Operating Environment
Operate the servo amplifier in the following environment. The servo amplifier is neither dust proof nor
1
water proof.
Ambient temperature -10 [°C] to +55 [°C] (no freezing allowed)
Ambient humidity
Observe the following when operating.
Install indoors at a place free from rainwater and direct sunshine.
Do not operate in corrosive atmosphere including hydrogen sulfides, sulfurous acid, chlorine,
ammonia, sulfur, chlorine-based gases, acids, alkalis or salts or near flammable gases or matters.
Install in a well ventilated environment with less vapor, oil and water content.
Install at a place with less vibration.
Use in locations with oil, water vapor or corrosive gas, or in dusty locations
Use in intense electric fields or in ferromagnetic fields
Use in the same control panel as that used for high-voltage (2 kV) equipment
Use with the same power supply as devices which generate a lot of noise
Other surrounding environments in which use prohibited
(i) Locations with powerful electromagnetic waves
(ii) Vacuum
(iii) In explosive atmosphere
(iv) Under acceleration, vibration conditions
1-8
Servo Amplifier
Item
10 [%] to 90 [%] RH (no condensation allowed)
Indoors at altitude ≤ 1000 [m] free from powder dust,
Location
corrosive gases and direct sunshine
3 mm(Max. amplitude): less than 2 to 9 Hz,
2
9.8 m/s
Vibration
2
2 m/s
: less than 20 to 55 Hz,
2
1 m/s
: less than 55 to 200 Hz
Environmental condition
: less than 9 to 20 Hz,