2.1.3.5

Analog Monitor Output (MON1, MON2, M5)

The analog monitor output is the analog voltage output terminal of the servo amplifier. The output is
specified with a parameter.
Observe after 2 seconds or longer have elapsed since turning ON the power.
The output voltage will be unstable immediately after turning ON the power, and after turning OFF the
power.
 Max. ±10 [V]/0.5 [mA]
 Resolution: 14-bit/± full scale
2.1.3.6
Sequence Input (CONT1, CONT2, CONT3, ... COMIN)
These are input terminals for sequence control.
 They are compatible with both sink input and source input.
 Use in the 12 to 24 VDC range.
 Approximately 8[mA] (for 24 VDC) is consumed per point.
 Terminal functions are set with parameters.
Refer to "2.5.3 Signal Descriptions" onward for details on assignable signals.
COMI N
DC12 ~ 24V
CONT n
Servo amplifier
(Sink input)
MON1
MON2
Servo amplifier
サーボアンプ
M5
0V
3k
CHAPTER 2 WIRING
COMI N
3k
DC12 ~ 24V
CONTn
Servo amplifier
(Source input)
Configuration
2
2-15